Hi-Rel COTS Environmental Screening

VPT's converters and EMI filters are available with targeted screening grades to satisfy a wide range of requirements. Additional custom environmental screening may be performed to meet each customer's needs. Please contact a sales representative concerning different environmental screenings.

 

Screening Condition
Internal Visual IPC-A-610
Stabilization Bake MIL-STD-883, Method 1008, Condition B, 125° C, 24 hours
Temperature Cycling

MIL-STD-883, Method 1010, Condition B, -55° C to +125° C, 10 cycles

Burn-In MIL-STD-883, Method 1015, 96 hours at +100° C
Final Electrical

100% at 25° C

External Visual

MIL-STD-883, Method 2009