VPT100+2800S DC-DC Converter

This "plus" version of our VPT100-2800S Series delivers parallel operation of up to five units with current sharing, all in a single cost-effective package. Extremely efficient in a tiny quarter brick size, this series is ideal for avionics, ground systems, and other applications.

 

View the technical overview video for this series.

  • Up to 100W output power per unit
  • Single outputs of 3.3V, 5V, 7V, 12V, 15V and 28V
  • Very high efficiency – up to 91%
  • Very low output noise
  • Wide input voltage range: 16 to 40 Volts per MIL-STD-704
  • Manufactured to J-STD-001, ISO9001, and IPC-A-610
  • Operation over a wide -55°C to +100°C STANDARD
  • Output voltage trim up +10% or down -20%
  • Six-sided metal cases for improved EMI performance and mechanical/environmental performance
  • NO use of optoisolators for ultimate reliability
  • Undervoltage lockout
  • Indefinite short circuit protection
  • Current limit protection
  • High input transient voltage: 50 Volts for 1 sec 
  • Environmental screening including a 96 hour burn-in, 100% electrical testing, and temperature cycling testing STANDARD
  • Meets MIL-STD-461C/D/E conducted emissions requirements when used with a VPTF Series EMI filter 

To provide you with the most accurate data for the actual performance of this product once deployed, please note that the electrical performance data provided below is at Tcase = -55° C to 100° C, Vin= +28V +-5%, full load, unless otherwise specified.

Parameter Conditions VPT100+283R3S VPT100+2805S VPT100+2807S Units
Min Typ Max Min Typ Max Min Typ Max
Input
Voltage
Continuous
Transient(1)

16

28

40

50

16

28

40

50

16

28

40

50

Vdc
Output
Voltage
Full Load
3.217 3.20 3.383 4.875  5.00 5.125 6.825 7.00 7.175 Vdc
Output
Power(2)
Vin: 15-50V

0

 

66

0

 

100

0

 

100

W
Efficiency
Vin: 28V,
Full Load
85 90
85 90   87 90   %
Input
Ripple
Full Load,
20Hz to 10 MHz


180

200

200 mApp
Output
Ripple
Full Load,
20Hz to 10MHz


150  
150  
150 mVpp
Load
Regulation
No Load to
Full


50

50

70 mV
Line
Regulation
Vin: 16-40V


20  
20  
20 mV

(1) Transient time up to 1 second.
(2) Derate linearly to 0 at 110 deg. C. 

Parameter Conditions VPT100+2812S VPT100+2815S VPT100+2828S Units
Min Typ Max Min Typ Max Min Typ Max
Input
Voltage
Continuous
Transient(1)

16

28

40

50

16 28

40

50

16 28

40

50

Vdc
Output
Voltage
Full Load
11.70 12.00 12.30 14.625 15.00 15.375 27.16 28.00 28.84 Vdc
Output
Power(2)
Vin: 15-50V

0

 

100

0

 

100

0

 

100

W
Efficiency
Vin: 28V,
Full Load
87 90   87 91   85 88   %
Input
Ripple
Full Load,
20Hz to 10 MHz


200

200

200 mApp
Output
Ripple
Full Load,
20Hz to 10MHz
 
150  
150  
300 mVpp
Load
Regulation
No Load to
Full


100  
100

100 mV
Line
Regulation
Vin: 16-40V
 
20  
20  
50 mV

 

 




Products Services Literature New at VPT Company Contact Us
All Products
Avionics & Military DC-DC Converters
COTS DC-DC Converters
  VPT Series Metal DC-DC Modules
  COTS Potted DC-DC Modules
Space DC-DC Converters
EMI Filters, Transient Supporessors, Bus Converters
DSCC Qualified DC-DC Converters & Filters
Definition of Part Numbers
VME Power Supplies
Point-of-Load Converters
Thermal Mounting Pads
Recent Successes
Power System Design & Assembly
  Design Process
  Success Stories
  Technical Capabilities
Technical Design Assistance
Datasheets
Video Labs
Catalogs & Brochures
Application Notes
What's New
Upcoming Events
VPT in the News
Press Kit
Recent Successes
About VPT
Patents & Awards
Customers
Partners
Programs Supported
Facilities & Certifications
Careers
Request More Information
News by Email
Customer Satisfaction
Find a Sales Rep
Request More Information